Clinical care requirements

Orders and CPOE

Order entry, sets, communication, tracking, prior authorization.

How to read status labels: In the pilot (v0.5.0, synthetic data) Simulated in the pilot (no real external system) Designed, not yet built Open decision Not offered / no claim made Planned partner integration

C0647Does AuroraMed provide CPOE for medications, labs, imaging, procedures, referrals, nursing, diet, therapy, DME, blood and isolation?

The pilot covers part of this. The rest is designed, not built. Pilot detail: Orders piece: medication/lab/imaging/procedure/referral orders with sign, cosign, discontinue (no nursing/diet/therapy orders). REQ-0501 says the system must provide CPOE for medications, labs, imaging, procedures, referrals, nursing, diet, therapy, DME, blood and isolation. Its acceptance check: each order type has a registry definition and state machine.

In the pilot (v0.5.0, synthetic data)Permalink

C0648Can any clinician place any kind of order, or is ordering limited by role and licence?

REQ-0502 is a top-priority requirement for all three tiers: the system must require ordering authority by role and licensure and must restrict order types per role. The pilot covers part of this. The rest is designed, not built. Where the code stands: Basic MVP equivalent: patient banner/summary, vitals/note/I&O entries, stay/day/hour timeline, care assignment, results view; free-text, not coded or templated. To verify it, the specification says unauthorized order type is not offered.

In the pilot (v0.5.0, synthetic data)Permalink

C0649Does AuroraMed support order sets, panels, quick orders and preference lists with versioning?

The orders and cpoe part of the specification (REQ-0503) says the system must support order sets, panels, quick orders and preference lists with versioning. Designed, not built: there is no code for this in the pilot. Acceptance check: order set edits create a new version.

Designed, not yet builtPermalink

C0650Does AuroraMed support ask-at-order-entry questions?

How would it be tested? The specification says required questions block signature until answered. That is the check for REQ-0504: the system must support ask-at-order-entry questions. This is on the design side of the line. Nothing in v0.5.0 does it.

Designed, not yet builtPermalink

C0651Does AuroraMed support verbal/telephone orders with read-back and cosign deadlines?

The pilot covers part of this. The rest is designed, not built. Pilot detail: Verbal/telephone orders with read-back attestation and cosign deadline; status history and a state machine (ordered to resulted). For reference, REQ-0505 (a top-priority requirement, all three tiers) says the system must support verbal/telephone orders with read-back and cosign deadlines. Check: unsigned verbal order escalates after deadline (still an open decision). Parts of it are explicitly marked as open in the specification.

In the pilot (v0.5.0, synthetic data)Permalink

C0652Does AuroraMed support protocol/standing/pended/future/recurring orders?

The system must support protocol/standing/pended/future/recurring orders. That is REQ-0506, a high-priority requirement for all three tiers. Not yet. It is designed in the specification and not built in the pilot. Test in the specification: pended order cannot execute.

Designed, not yet builtPermalink

C0653Does AuroraMed track order status from ordered to final with a defined state machine?

The pilot covers part of this. The rest is designed, not built. In the pilot: Verbal/telephone orders with read-back attestation and cosign deadline; status history and a state machine (ordered to resulted). REQ-0507 says the system must track order status from ordered to final with a defined state machine. Its acceptance check: illegal transitions refused.

In the pilot (v0.5.0, synthetic data)Permalink

C0654Does AuroraMed emit and consume HL7 v2 orders/results and FHIR ServiceRequest/Task/DiagnosticReport?

REQ-0508 is a top-priority requirement for all three tiers: the system must emit and consume HL7 v2 orders/results and FHIR ServiceRequest/Task/DiagnosticReport. This is on the design side of the line. Nothing in v0.5.0 does it. To verify it, the specification says interface tests pass.

Designed, not yet builtPermalink

C0655Does AuroraMed check duplicate orders, medical necessity and authorization requirements?

The orders and cpoe part of the specification (REQ-0509) says the system must check duplicate orders, medical necessity and authorization requirements. No. The specification describes it, but the pilot does not include it. Acceptance check: duplicate warns with links to existing order.

Designed, not yet builtPermalink

C0656Does AuroraMed show appropriate-use criteria for advanced imaging where required?

How would it be tested? The specification says aUC consultation id stored with order. That is the check for REQ-0510: the system must show appropriate-use criteria for advanced imaging where required. Not yet. It is designed in the specification and not built in the pilot.

Designed, not yet builtPermalink

C0657Does AuroraMed optionally display cost of care at order entry?

Designed, not built: there is no code for this in the pilot. For reference, REQ-0511 (a lower-priority requirement, the large tier only) says the system must optionally display cost of care at order entry. Check: displayed price matches charge master.

Designed, not yet builtPermalink

C0658Does AuroraMed reconcile orders at transfer, admission and discharge?

The system must reconcile orders at transfer, admission and discharge. That is REQ-0512, a top-priority requirement for the medium and large tiers. This is on the design side of the line. Nothing in v0.5.0 does it. Test in the specification: discharge reconciliation blocks discharge orders if unresolved (per site policy).

Designed, not yet builtPermalink

C0659Does AuroraMed verify consent before blood product orders?

No. The specification describes it, but the pilot does not include it. REQ-0513 says the system must verify consent before blood product orders. Its acceptance check: missing transfusion consent blocks non-emergency order.

Designed, not yet builtPermalink

C0660Does AuroraMed support referral/consult orders with closed-loop tracking?

REQ-0514 is a high-priority requirement for all three tiers: the system must support referral/consult orders with closed-loop tracking. Not yet. It is designed in the specification and not built in the pilot. To verify it, the specification says unclosed referral appears on worklist.

Designed, not yet builtPermalink

C0661Does AuroraMed support DME/home-health/SNF orders with face-to-face documentation?

The orders and cpoe part of the specification (REQ-0515) says the system must support DME/home-health/SNF orders with face-to-face documentation. Designed, not built: there is no code for this in the pilot. Acceptance check: f2F date required.

Designed, not yet builtPermalink

C0662Does AuroraMed support electronic lab ordering to external networks and bi-directional interfaces?

How would it be tested? The specification says order sent and result matched by accession. That is the check for REQ-0516: the system must support electronic lab ordering to external networks and bi-directional interfaces. This is on the design side of the line. Nothing in v0.5.0 does it.

Designed, not yet builtPermalink

C0663Does AuroraMed support electronic prior authorization (X12 278, Da Vinci PAS, NCPDP ePA) and real-time prescription benefit?

No. The specification describes it, but the pilot does not include it. For reference, REQ-0517 (a high-priority requirement, the medium and large tiers) says the system must support electronic prior authorization (X12 278, Da Vinci PAS, NCPDP ePA) and real-time prescription benefit. Check: pA request and response linked to order.

Designed, not yet builtPermalink

C0664Does AuroraMed provide order entry on approved mobile devices?

The system must provide order entry on approved mobile devices. That is REQ-0518, a medium-priority requirement for the medium and large tiers. Not yet. It is designed in the specification and not built in the pilot. Test in the specification: mobile enforces same authorization.

Designed, not yet builtPermalink

C0665Does AuroraMed mark AI-generated order suggestions as drafts requiring explicit signature?

Designed, not built: there is no code for this in the pilot. REQ-0519 says the system must mark AI-generated order suggestions as drafts requiring explicit signature. Its acceptance check: aI draft cannot be signed automatically.

Designed, not yet builtPermalink