AuroraMed v0.5.0 is a synthetic-data pilot. See exactly what's built →

Resources

Integrations: everything is simulated or absent

The pilot has no live external connections. Several are built as simulators inside the hub. This page lists each integration and its truth. Listing a standard is not a claim of conformance.

IntegrationStatusWhat is true
Lab (HL7 v2)Simulated in the pilot (no real external system)A simulated reference-lab connector speaks HL7 v2 orders and results inside the hub, with LOINC-coded results. Parsing, wrong-patient rejection and masking are real code. No real laboratory or analyzer is connected.
Imaging (DICOM, PACS, RIS)Simulated in the pilot (no real external system)Simulated report ingestion with impression and critical-finding flag. No DICOM, no image viewing.
E-prescribing, PDMPSimulated in the pilot (no real external system)Simulated pharmacies (simplified NCPDP-style messages) and a simulated monitoring check. No real pharmacy network.
EPCS (DEA)Designed, not yet builtNot built and not claimed.
Clearinghouse, eligibility, claims (X12)Simulated in the pilot (no real external system)A simulated clearinghouse handles 270/271, 837P, 999 and 835 style messages. No payer is connected.
FHIR R4 (read-only)Simulated in the pilot (no real external system)A read-only FHIR R4-style interface answers from inside the hub. No partner is connected and no conformance is claimed.
HL7 v2 ADTSimulated in the pilot (no real external system)Admit, discharge, registration and update messages go out to an in-process simulated partner; inbound messages are validated and not applied.
SMART, C-CDA, Direct, TEFCADesigned, not yet builtPlanned. Versions are marked to verify.
SMS, pager, overhead pagingDesigned, not yet builtNot built.
Elyria transport ordersPlanned partner integrationOptional, separate company. Details.

Terminology bundled in the pilot

SetContentComplete?
ICD-10-CM14,594 codes in curated categoriesSubset
RxNorm1,367 conceptsSubset
CVX immunizations290 codesComplete as of September 30, 2026
UNII allergens29Small subset
LOINC50 curated codesTiny subset
SNOMED CT, CPTNot bundledLicences needed

The design places every interface behind an on-site interface engine with persistent queues and mutually authenticated connections. That is an architecture document, not code; today the simulators live inside the hub.

Need a specific connection?

Tell us which system, and we will tell you where it sits on the plan.

See the synthetic-data demo first.Request a demo