Resources
Integrations: everything is simulated or absent
The pilot has no live external connections. This page lists each integration and its truth. Listing a standard is not a claim of conformance.
| Integration | Status | What is true |
|---|---|---|
| Lab (HL7 v2) | Simulated in the pilot | Authorised synthetic roles inject results through an internal interface. No HL7 feed or analyzer connection. |
| Imaging (DICOM, PACS, RIS) | Simulated in the pilot | Same internal interface. No image viewing. |
| E-prescribing, EPCS, PDMP | Designed, not yet built | Not built. |
| Clearinghouse, eligibility, claims (X12) | Designed, not yet built | Not built. |
| FHIR R4, SMART, C-CDA, Direct, TEFCA | Designed, not yet built | Planned. Versions are marked to verify. |
| SMS, pager, overhead paging | Designed, not yet built | Not built. |
| Elyria transport orders | Planned partner integration | Optional, separate company. Details. |
Terminology bundled in the pilot
| Set | Content | Complete? |
|---|---|---|
| ICD-10-CM | 14,594 codes in curated categories | Subset |
| RxNorm | 1,367 concepts | Subset |
| CVX immunizations | 290 codes | Complete as of September 30, 2026 |
| UNII allergens | 29 | Small subset |
| LOINC | 50 curated codes | Tiny subset |
| SNOMED CT, CPT | Not bundled | Licences needed |
The design places every interface behind an on-site interface engine with persistent queues and mutually authenticated connections. That is an architecture document, not code.
Need a specific connection?
Tell us which system, and we will tell you where it sits on the plan.