The pilot has no live external connections. Several are built as simulators inside the hub. This page lists each integration and its truth. Listing a standard is not a claim of conformance.
| Integration | Status | What is true |
|---|---|---|
| Lab (HL7 v2) | Simulated in the pilot (no real external system) | A simulated reference-lab connector speaks HL7 v2 orders and results inside the hub, with LOINC-coded results. Parsing, wrong-patient rejection and masking are real code. No real laboratory or analyzer is connected. |
| Imaging (DICOM, PACS, RIS) | Simulated in the pilot (no real external system) | Simulated report ingestion with impression and critical-finding flag. No DICOM, no image viewing. |
| E-prescribing, PDMP | Simulated in the pilot (no real external system) | Simulated pharmacies (simplified NCPDP-style messages) and a simulated monitoring check. No real pharmacy network. |
| EPCS (DEA) | Designed, not yet built | Not built and not claimed. |
| Clearinghouse, eligibility, claims (X12) | Simulated in the pilot (no real external system) | A simulated clearinghouse handles 270/271, 837P, 999 and 835 style messages. No payer is connected. |
| FHIR R4 (read-only) | Simulated in the pilot (no real external system) | A read-only FHIR R4-style interface answers from inside the hub. No partner is connected and no conformance is claimed. |
| HL7 v2 ADT | Simulated in the pilot (no real external system) | Admit, discharge, registration and update messages go out to an in-process simulated partner; inbound messages are validated and not applied. |
| SMART, C-CDA, Direct, TEFCA | Designed, not yet built | Planned. Versions are marked to verify. |
| SMS, pager, overhead paging | Designed, not yet built | Not built. |
| Elyria transport orders | Planned partner integration | Optional, separate company. Details. |
Terminology bundled in the pilot
| Set | Content | Complete? |
|---|---|---|
| ICD-10-CM | 14,594 codes in curated categories | Subset |
| RxNorm | 1,367 concepts | Subset |
| CVX immunizations | 290 codes | Complete as of September 30, 2026 |
| UNII allergens | 29 | Small subset |
| LOINC | 50 curated codes | Tiny subset |
| SNOMED CT, CPT | Not bundled | Licences needed |
The design places every interface behind an on-site interface engine with persistent queues and mutually authenticated connections. That is an architecture document, not code; today the simulators live inside the hub.
Need a specific connection?
Tell us which system, and we will tell you where it sits on the plan.